While it is open
Insulate the attic and walls, seal the ducts and choose the windows while the house is open.
Free 3D design for any room in your home, siding or roof, before you sign · 10% off for veterans and seniorsFree 3D design · 10% off for veterans and seniors
Energy-efficient remodeling · Sacramento
In a Sacramento remodel, the best time for energy upgrades is while the attic, walls or roof are already open: insulation, air sealing, sealed ducts and better windows. US Construction Remodeling can plan those upgrades with the rest of the remodel, apply for the permit and line up the energy tests.
Permits applied for since January 1, 2026 follow the 2025 California Energy Code. Below: what to upgrade for lower utility bills and long-term operating costs, the rules for windows, roofs, attics, ducts and water heaters, materials, and what happened to the federal tax credits.

Insulate the attic and walls, seal the ducts and choose the windows while the house is open.
Replacement windows need a U-factor of 0.27 and an SHGC of 0.23 or lower, and most heating and cooling changes need an ECC-Rater test.
The federal home energy credits ended for work after December 31, 2025.
While it is open
A remodel opens the attic, walls, roof or ducts. That is the easiest time to insulate, seal and upgrade them, before they are closed again.

When attic insulation is added or replaced, or a completely new duct system goes into the attic, the 2025 Energy Code calls for R-49 in the Sacramento area. Many homes also need the gaps in the ceiling below sealed, recessed lights buried in the insulation and the attic kept vented. An attic that already has R-38 is exempt, among other exceptions.
When drywall comes off, or siding comes off a wall with no sheathing behind it, the stud bays are open. The Energy Commission calls an open wall the opportunity to insulate it before it is closed. More in siding and walls.
Ducts in the attic are easiest to seal or replace while the attic is open. ENERGY STAR says a typical duct system loses about 20 to 30 percent of the air moving through it to leaks, holes and poorly connected ducts.
When more than half of the roof is replaced, a steep roof in climate zones 11 and 12 needs a cool roof product. Its aged solar reflectance is at least 0.20 and its thermal emittance at least 0.75, or its Solar Reflectance Index (SRI) is at least 16. Exceptions include an attic with R-38 insulation or a radiant barrier, and in climate zone 12 a house with no ducts in the attic. Low-slope roofs need higher reflectance and added roof insulation.
If the wall around a window is open, replacing the window then saves opening the wall twice. The numbers new windows need are in windows and doors.
The 2025 code
Permits applied for since January 1, 2026 follow the 2025 Energy Code. It applies to what you change and the parts tied to it, such as the ducts on a new furnace, not to the whole house.
The Energy Commission’s ZIP code list puts Sacramento, Elk Grove, Folsom, Rancho Cordova, Citrus Heights and El Dorado Hills in climate zone 12, and Roseville and Rocklin in climate zone 11. Most rules in this guide are the same in both.
Lighting is an example: the Energy Commission’s manual says only the lighting equipment that is altered needs to comply. Fixtures you keep can stay.
Energy work on a permit carries compliance forms. A CF1R goes in with the application, and the installer completes a CF2R before the final inspection.
Since January 1, 2026, the field tests once done under the HERS program are done by an ECC-Rater, under the state’s Energy Code Compliance Program. They are required for most heating and cooling changes, and the rater may have no financial interest in the contractor. Attic insulation is checked by the building inspector.
The City of Sacramento lists window replacements, water heaters, skylights, re-roofing and siding among the work that needs a building permit. Heating and air conditioning change-outs are minor permits, which a licensed contractor can get online.
Our permits page explains how we handle permits and inspections.
Permits and inspectionsRemodeling an older homeWindows and doors
Replacement windows must meet the 2025 Energy Code numbers printed on their NFRC label.
In climate zones 11 and 12, replacement windows need a U-factor of 0.27 or lower and a solar heat gain coefficient (SHGC) of 0.23 or lower. A lower U-factor keeps more heat in, and a lower SHGC lets less of the summer sun’s heat through.
When 75 square feet or less of window area is replaced, the code allows a U-factor up to 0.40 and an SHGC up to 0.35.
The NFRC label shows both numbers. The temporary label stays on the glass until the inspector has seen it.
An ENERGY STAR label does not mean a window meets the California code. ENERGY STAR allows a U-factor of 0.28 in Sacramento County and an SHGC of 0.40 in Placer and El Dorado counties, so check the NFRC numbers.
Where a remodel adds door area, the new door needs a U-factor of 0.20 or lower. Doors that are at least one-quarter glass follow the window numbers.
A kitchen remodel often opens the wall around the window over the sink or a patio door. Replacing them at the same time means the new cabinets, tile and paint are not disturbed later.
Our Sacramento window guide covers sizes, egress rules and safety glass.
Replacement windows in SacramentoWindow replacementSiding and walls
New siding is the moment to fix the layers behind it: the water-resistive barrier, the flashing and the insulation.
Behind the siding, house wrap or building paper sheds the water that gets past the boards. Each course laps over the one below it, so water runs down and out.
Every window and door opening gets flashing folded into the barrier, so water at the corners is led out of the wall, not into it.

Where the sheathing comes off or was never there, the open stud bays can be insulated before new sheathing and wrap go on. Where it stays, insulation can be blown into the bays through small holes. The 2025 code level for wood walls is R-15 in 2x4 framing and R-21 in 2x6, and 2x4 walls that already have R-11 are exempt.
Soft or stained sheathing is replaced before the new layers go on. See plywood or OSB under siding.
Siding that holds up for decades is replaced less often. Our James Hardie guide compares fiber cement with other siding for Sacramento homes.
Planning new siding? See our siding page and the James Hardie guide.
SidingIs James Hardie siding worth it?Heating and cooling
Insulation, air sealing and better windows lower the heat a house gains and loses, so the heating and cooling system is chosen after that work is planned.
A system sized for a leaky, poorly insulated house can be larger than the house needs after the upgrades. A room-by-room load calculation sets the size.

When the furnace or air handler, the outdoor unit or a coil is replaced, the connected ducts must be sealed and tested by an ECC-Rater. The usual limit is leakage of 10 percent or less of the system airflow, or 7 percent or less to the outside.
Duct systems under 40 feet long, and systems already sealed and verified by a test, are among the exceptions.
When more than 25 feet of new or replacement duct is installed, new ducts in the attic or another unconditioned space need R-8 insulation in climate zones 11 and 12, and the ducts are sealed and tested. A completely new duct system must leak 5 percent or less.
When an air conditioner or heat pump gets new refrigerant parts, its refrigerant charge and airflow are verified, and every thermostat on the system becomes a programmable setback thermostat.
A replaced heating system generally may not use electric resistance as its main heat source, while a gas furnace or a heat pump is allowed. Electric wall or baseboard heaters can be replaced with the same kind.
Try our HVAC sizing calculator for a first estimate before you choose a system.
HVAC sizing calculatorGet my free estimateWater and lighting
Water heating and lighting rules apply to the equipment you replace.

A heat pump water heater moves heat from the surrounding air into the water. It needs air space around it, a drain for the water it condenses and usually its own electric circuit.
When a water heater is replaced, the 2025 code allows a natural gas or propane water heater, or a heat pump water heater. Under the basic heat pump option the tank may not sit outdoors, sits on an insulated base of at least R-10 and has a communication port. An electric water heater may replace an electric one.

For new fixtures in an addition, CALGreen sets 1.28 gallons per flush for toilets, 1.8 gallons per minute for showerheads, 1.2 for bathroom faucets and 1.8 for kitchen faucets. Low-flow showerheads and faucets also cut the energy used to heat the water.
New light fixtures must meet the code’s high-efficacy rules. In a bathroom, at least one light turns off on its own with an occupancy or vacancy sensor, and kitchen lights generally get wall dimmers.
Replacing a water heater or remodeling a bathroom? See our service pages.
Water heater replacementBathroom remodelingMaterials
Sustainable choices come down to what lasts, what the materials release indoors and how little ends up in the landfill.
CALGreen’s VOC limits for paints, adhesives, sealants and caulks are a rule for additions. In any remodel, low-VOC or zero-VOC products can be chosen.
CALGreen also holds hardwood plywood, particleboard and MDF, the boards inside many cabinets and shelves, to the state’s formaldehyde limits.
In an addition, CALGreen calls for recycling or salvaging at least 65% of the construction and demolition waste. Sorting metal, wood and concrete on site makes that possible.
Siding, roofing and windows that last longer are replaced less often, which lowers replacement costs and the waste over the life of the house.
Sound cabinet boxes can be refaced instead of replaced, and solid doors and trim can be reused.
Tax credits
Not federal ones. The two federal credits for home energy upgrades ended for work after December 31, 2025.
This credit covered items such as qualifying windows, doors, insulation and heat pumps. The IRS says it is not allowed for any property placed in service after December 31, 2025.
This credit covered systems such as solar panels. It is not allowed for expenditures made after December 31, 2025, and an installation completed after that date counts as made after it.
How we help
US Construction Remodeling can plan the energy work with the rest of the remodel, so each part is done while it is open.
We walk the house with you and list what can be upgraded while the attic, walls, roof or ducts are open, with each item priced as its own line.
We always apply for the permit ourselves, handle the energy forms and schedule each inspection and the ECC-Rater’s tests.
We choose windows, roofing and water heaters that meet the 2025 code for your climate zone, and we leave the temporary NFRC labels on until the inspector has seen them.
For your own records, we give you the NFRC numbers, the product sheets and an itemized invoice for each product we install.
Windows, siding, roofs, kitchens, bathrooms, water heaters and whole-home remodels, under one contract.
Wondering which upgrades pay back when you sell? Our remodeling return guide covers it.
Remodeling return in SacramentoGet my free estimateAbout the author
Our Chief Designer wrote this guide.
Chief Designer
Emin is the Chief Designer at US Construction Remodeling Corp. Emin leads client design meetings, measured layouts and 3D visualization in Revit, 3ds Max and Unreal Engine, and uses AI tools to speed up design and project planning.
Sources
The California Energy Commission, the IRS, ENERGY STAR, the state housing department and the City of Sacramento.
Permits applied for on or after January 1, 2026 follow the 2025 Energy Code.
Window values (Table 150.1-A), wall insulation, and the alteration rules for roofs, attics, ducts, cooling systems and water heaters (Section 150.2).
Examples for remodels: open walls, attic work, lighting and the energy forms.
Climate zone 12 for Sacramento, Elk Grove, Folsom, Rancho Cordova, Citrus Heights and El Dorado Hills; zone 11 for Roseville and Rocklin.
The Energy Code Compliance Program and its raters.
The ECC Program replaced HERS field testing on January 1, 2026.
What a cool roof is and who rates the products.
The label with solar reflectance and thermal emittance values.
ENERGY STAR window, door and skylight criteria by climate zone.
Sacramento County is in the ENERGY STAR South-Central zone.
How much air a typical duct system loses.
The end dates of the 25C and 25D credits.
What the Energy Efficient Home Improvement Credit covered.
Fixture flow rates, low-VOC products, composite wood and waste recycling, and when CALGreen applies to a remodel.
Work that needs a building permit in the City of Sacramento.
Water heater, heating and cooling, and re-roof permits online.
The energy forms and rated roofing products for a re-roof permit.
California contractor license #1117562 on the state license board.
Practical questions
Short answers about windows, insulation, ducts, water heaters and tax credits.
The ones that slow the heat moving in and out of the house: attic insulation with air sealing, sealed ducts, insulated walls and windows that meet the 2025 code. They are easiest to add while the attic, walls or ducts are already open.
In climate zones 11 and 12, which cover Sacramento and the nearby cities, a U-factor of 0.27 or lower and an SHGC of 0.23 or lower. When 75 square feet or less of window area is replaced, a U-factor of 0.40 and an SHGC of 0.35 are allowed.
No. The IRS says the Energy Efficient Home Improvement Credit is not allowed for any property placed in service after December 31, 2025.
In most cases, yes. When the furnace or air handler, the outdoor unit or a coil is replaced, the connected ducts are sealed and tested by an ECC-Rater, unless an exception applies, such as ducts under 40 feet long.
It is a good time to look. If there is no sheathing behind the siding, or the sheathing is replaced, the stud bays are open and can be insulated; where the sheathing stays, insulation can be blown in through small holes. The 2025 code level for wood walls is R-15 in 2x4 framing and R-21 in 2x6.
When attic insulation is added or replaced, or a completely new duct system goes into the attic, the 2025 Energy Code calls for R-49 in the Sacramento area. An attic that already has R-38 or more is exempt.
Yes. When a water heater is replaced, the 2025 Energy Code allows a heat pump water heater, and it still allows a natural gas or propane one. A heat pump unit needs air space around it, a condensate drain and usually its own circuit.
Yes. The City of Sacramento lists window replacements among the work that needs a building permit, and the temporary NFRC label stays on the glass until the inspector has seen it.
Plan your project
Send your address and what you want to change. The visit is free, and we send a written price, line by line, for each upgrade.
US Construction Remodeling Corp. · CSLB #1117562 · 4424 Freeport Blvd. STE 4, Sacramento, CA 95822
Keep planning
Our service pages and the guides that go with this one.