05 · Treating tile as waterproofingThe shower needs a complete water-management system.
Tile and grout alone do not make a tiled shower waterproof. The substrate, waterproofing, drain connection, corners, penetrations and transitions must work together. A missed connection can allow water into areas you cannot see.
Ask which assembly will be installed and how it will be checked before tile. For example, Schluter describes a pre-tile water test as a quality-control check for its shower system. Follow the system’s instructions and your building department’s rules for preparation, curing, testing and inspection. Leave the connections open until the required checks are done.
A useful record identifies the system, test date, result and any correction or retest. A manufacturer’s procedure and a required municipal inspection are separate checks. Read the manufacturer’s water-test explanation.
Ask: “What will be checked before tile, who records the result, and what happens if it fails?”
06 · Assuming fan noise means ventilation worksConfirm where the moist air goes.
Waterproofing manages liquid water; ventilation removes moisture from the air. A fan can run while a poor duct route or outdoor termination limits its usefulness. Review fan selection, duct routing, controls and access together.
EPA guidance calls for bathroom exhaust to discharge outdoors, not into the attic. Include an operating check and an explanation of the controls at handover. EPA moisture-control guidance.
Ask: “Where does the fan exhaust, and how should we operate it after a shower?”